Customization: | Available |
---|---|
Type: | Asphalt Mixing Plant |
Moving Type: | Fixed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Equipment Name | Asphalt mixing plants |
Rated production capacity | 80t/h |
Model | CSM80 |
Aggregate Specification | |
Agg. temp of discharge end of drying drum | 120-170ºC |
Nomal atmospheric pressure | 760 mmHg |
Ambient temperature | 20ºC |
Specific gravity of aggregate | 1650 kg/m3 |
Aggregates moisture content | ≤5% |
Aggregates specific heat | 0.21 Kcal/kgºC |
Filler content | 5% |
Fuel calorific value | |
Diesel | 10,500 Kcal/kg |
Fuel calorific value | 5% |
Electrical Design | |
Single phase | 220v |
Three phase | 380v |
Frequency | 50HZ |
Productivity | 80t/h | |
Feeding bin volume | 1.1 m3×2 | |
Mixture output | 1.1 m3×2 | |
Agg. size | <=50mm | |
Agg. bins | 4 bins,single volume:5m3 ,cumulative measurement | |
Weighing range and static measurement accuracy | Agg. | ≤2000kg±0.5% |
Filler | ≤200kg±0.5% | |
Bitumen | ≤200kg±0.25% | |
Products temp | 120~170 ºC, (adjustable) |
No. | Item name | Technical parameter | |
1 | rated capacity | 80t/h(working standard) | |
2 | charge-in capacity | 1.1m3 ×2 | |
3 | charge-in weighting | 1.8t/hodful×2 | |
4 | out-put temp | 120-170ºC(Adjustable) | |
5 | applicability | Bitumen, asphalt dinas, asphalt sand | |
6 | fuel consumption | fuel oil:5.5-7.5kg/t, mixture | |
7 | drying drum rotate speed | 20.2 Turn/min | |
8 |
assort total power | 196kW(include water dust filter) 193kW(include Bag dust removal) |
|
mixer power | 22 kw ×2 | ||
drum-drive power | 18.5 kw×2 (Variable frequency starting) |
||
burner power | 7 kw×2 | ||
dust catcher power | water dust filter(37kW) | ||
bag dust removal (45 kW) | |||
agg elevate power | 7.5 kW×2 | ||
filler screw conveyor power | 3 kw | ||
coarse ash power | 5.5kw | ||
aggregate weight conveyor power | 7.5 kw | ||
finished product elevate power | 11kw | ||
air compressor power | 11 kw | ||
submersible pump | 5.5kw×2 | ||
9 | control-drive way | PLC Programmable electrical control | |
10 | Dynamic measuring precision | aggregate | ±2.5% |
filler | ±2.5% | ||
bitumen | ±2% | ||
11 | Power | voltage | A.C 380V |
frequency | 50Hz |